Model
|
SUN-70K-G03
|
SUN-75K-G03
|
SUN-80K-G03
|
SUN-90K-G03
|
SUN-100K-G03
|
SUN-110K-G03
|
|
|
|
|
|
|
|
Max. DC Input Power (kW)
|
91
|
97.5
|
104
|
135
|
150
|
150
|
|
|
|
|
|
|
|
Max. DC Input Voltage (V)
|
1000
|
|
|
|
|
|
|
|
Start-up DC Input Voltage (V)
|
250
|
|
|
|
|
|
|
|
MPPT Operating Range (V)
|
200~850
|
|
|
|
|
|
|
|
Max. DC Input Current (A)
|
' 40+40+40+40
|
40+40+40+40+40+40
|
|
|
|
|
|
|
|
Max. Short Circuit Current (A)
|
60+60+60+60
|
60+60+60+60+60+60
|
|
|
|
|
|
|
|
No.of MPP Trackers
|
4
|
6
|
|
|
|
|
|
|
|
No.of Strings per MPP Tracker
|
4
|
|
|
|
|
|
|
|
Output Side
|
|
|
|
|
|
|
|
|
Rated Output Power (kW)
|
70
|
75
|
80
|
90
|
100
|
110
|
|
|
|
|
|
|
|
Max. Active Power (kW)
|
77
|
82.5
|
88
|
99
|
110
|
121
|
|
|
|
|
|
|
|
Nominal Output Voltage / Range (V)
|
3L/N/PE 220/380V, 230/400V
|
|
|
|
|
|
|
|
Rated Grid Frequency (Hz)
|
50 / 60 (Optional)
|
|
|
|
|
|
|
|
Operating Phase
|
Three phase
|
|
|
|
|
|
|
|
Rated AC Grid Output Current (A)
|
106.1/101.5
|
113.6/108.7
|
121.2/115.9
|
136.4/130.4
|
151.5/144.9
|
166.7/159.4
|
|
|
|
|
|
|
|
Max. AC Output Current (A)
|
116.7/111.6
|
125/119.6
|
133.3/127.5
|
150/143.5
|
166.7/159.4
|
183.3/175.4
|
|
|
|
|
|
|
|
Output Power Factor
|
0.8 leading to 0.8 lagging
|
|
|
|
|
|
|
|
Grid Current THD
|
<3%
|
|
|
|
|
|
|
|
DC Injection Current (mA)
|
<0.5%
|
|
|
|
|
|
|
|
Grid Frequency Range
|
47~52 or 57~62 (Optional)
|
|
|
|
|
|
|
|
Efficiency
|
|
|
|
|
|
|
|
|
Max. Efficiency
|
98.8%
|
|
|
|
|
|
|
|
Euro Efficiency
|
98.3%
|
|
|
|
|
|
|
|
MPPT Efficiency
|
>99%
|
|
|
|
|
|
|
|
Protection
|
|
|
|
|
|
|
|
|
DC Reverse-Polarity Protection
|
Yes
|
|
|
|
|
|
|
|
AC Short Circuit Protection
|
Yes
|
|
|
|
|
|
|
|
AC Output Overcurrent Protection
|
Yes
|
|
|
|
|
|
|
|
Output Overvoltage Protection
|
Yes
|
|
|
|
|
|
|
|
Insulation Resistance Protection
|
Yes
|
|
|
|
|
|
|
|
Ground Fault Monitoring
|
Yes
|
|
|
|
|
|
|
|
Anti-islanding Protection
|
Yes
|
|
|
|
|
|
|
|
Temperature Protection
|
Yes
|
|
|
|
|
|
|
|
Integrated DC Switch
|
Yes
|
|
|
|
|
|
|
|
Remote software upload
|
Yes
|
|
|
|
|
|
|
|
Remote change of operating parameters
|
Yes
|
|
|
|
|
|
|
|
Surge protection
|
DC Type II / AC Type II
|
|
|
|
|
|
|
|
General Data
|
|
|
|
|
|
|
|
|
Size (mm)
|
838W×568H×324D
|
838W×568H×346D
|
|
|
|
|
|
|
|
Weight (kg)
|
81
|
|
|
|
|
|
|
|
Topology
|
Transformerless
|
|
|
|
|
|
|
|
Internal Consumption
|
<1W (Night)
|
|
|
|
|
|
|
|
Running Temperature
|
-25~65℃, >45℃ derating
|
|
|
|
|
|
|
|
Ingress Protection
|
IP65
|
|
|
|
|
|
|
|
Noise Emission (Typical)
|
<55 dB
|
|
|
|
|
|
|
|
Cooling Concept
|
Smart cooling
|
|
|
|
|
|
|
|
Max. Operating Altitude Without Derating
|
2000m
|
|
|
|
|
|
|
|
Warranty
|
5 years
|
|
|
|
|
|
|
|
Grid Connection Standard
|
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
|
|
|
|
|
|
|
|
Operating Surroundings Humidity
|
0-100%
|
|
|
|
|
|
|
|
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
|
|
|
|
|
|
|